The short version of Stationary phase fits in a sentence. The long version — which is the one that helps — is below.
Reviewed 2026-08-01. Anything still debated is marked as such rather than presented as settled.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample by passing them through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in how analytes partition between the mobile phase and the stationary phase cause them to exit the column at different times. Detection then records a signal proportional to the amount of each separated substance. The resulting chromatogram provides retention times and peak areas for identification and quantification.
Instrumentation includes a solvent delivery system, an autosampler, a column oven, and one or more detectors. Reversed-phase columns with chemically modified silica are widely used, but normal-phase, ion-exchange, size-exclusion, and affinity modes exist for specific separations. Detectors may rely on ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry. Column temperature, mobile phase composition, and flow rate are adjusted to improve resolution. System pressure is monitored because rising pressure can indicate column blockage or deteriorating packing.
Method validation examines whether an HPLC procedure is suitable for its intended purpose. Common parameters include accuracy, precision, specificity, linearity, range, detection limit, quantification limit, and robustness. Accuracy describes closeness to a true or accepted value, while precision describes agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from related substances. Robustness tests small deliberate changes in flow, temperature, or solvent composition. Validation is not a one-time event; methods may need partial revalidation after changes to instruments, columns, sample handling, or specification limits. Regulatory guidance provides frameworks, but some details remain method-specific.
Regulatory and pharmacopeial texts shape how HPLC testing is performed and documented. The International Council for Harmonisation provides validation guidance, while pharmacopeias publish general chromatography chapters and monographs for specific materials. Accreditation standards such as ISO/IEC 17025 address laboratory competence and traceability. Inspectors may review instrument qualification, analyst training, reference material control, and electronic records. Open questions include how best to validate methods for new complex products and how to handle automated data processing. Laboratories generally resolve these issues through risk assessment, method lifecycle management, and documented scientific justification.
| Property | Value | Notes |
|---|---|---|
| Separation principle | Differential partitioning | Analytes distribute between mobile and stationary phases. |
| Mobile phase | Liquid solvent mixture | Composition controls retention and selectivity. |
| Stationary phase | Packed column particles | Often chemically bonded silica. |
| Typical detector | UV-Vis or photodiode array | Mass spectrometry is also common. |
| Common synonym | High-performance liquid chromatography | Abbreviated as HPLC. |
Documentation and traceability are central to regulated HPLC testing. Records typically include instrument logs, column history, mobile-phase preparation, sample preparation, injection sequences, raw chromatograms, and audit trails. Electronic systems may require user access controls, time-stamped changes, and backup procedures. Training records show that analysts are qualified for assigned methods. Audits and inspections check whether written procedures match actual practice and whether deviations are documented. These controls support reproducibility and allow results to be reconstructed if questions arise later.
Method validation establishes that an HPLC procedure is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, robustness, and solution stability. Accuracy reflects closeness to a reference value, while precision reflects agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from matrix components. Validation is documented through protocols and reports, and the required extent depends on the method's use and regulatory context.
Routine quality control uses system suitability, blank injections, check standards, and control samples to detect drift or contamination. System suitability criteria may specify minimum resolution, maximum tailing factor, and a permitted range for repeated injections. Blank injections reveal carryover or solvent contamination, while check standards confirm calibration accuracy over a batch. Control samples with known analyte levels can show whether results remain within statistical limits. When a control result falls outside limits, the analyst investigates the cause and may invalidate affected results before repeating the batch.
Proper nutrition is important after delivery to help the mother recover, and to provide enough food energy and nutrients for a woman to breastfeed her child. Women having serum ferritin less than 70 μg/L may need iron supplements to prevent iron deficiency anaemia during pregnancy and postpartum. During lactation, water intake may need to be increased. Human milk is made of 88% water, and the IOM recommends that breastfeeding women increase their water intake by about 300 mL/day to a total volume of 3000 mL/day (from food and drink), approximately 2,400 mL/day from fluids. Fetal alcohol spectrum disorder Prenatal nutrition Smoking and pregnancy "Nutrition During Pregnancy Resource List for Consumers" (PDF). USDA NAL Food and Nutrition Information Center. Archived from the original (PDF) on 2007-07-14. Retrieved 2007-10-17. Health Education Authority (1996) Folic acid - what all women should know (leaflet) London:HEA
Laser-based bioprinting can be split into two major classes: those based on cell transfer technologies or photo-polymerization. In cell transfer laser printing, a laser stimulates the connection between energy-absorbing material (e.g. gold, titanium, etc.) and the bioink. This 'donor layer' vaporizes under the laser's irradiation, forming a bubble from the bioink layer which gets deposited from a jet. Photo-polymerization techniques rather use photoinitiated reactions to solidify the ink, moving the beam path of a laser to induce the formation of a desired construct. Certain laser frequencies paired with photopolymerization reactions can be carried out without damaging cells in the material. In this form of printing, plastic residues are melted down and individual layered in sections to create a desired shape. Nylon and PVA are examples of biomaterials used in this method. This technique is most often used to design prototypes for prosthetics and cartilage construction.
Sendai virus (family Paramyxoviridae) has a linear, single-stranded, negative-sense, nonsegmented RNA genome. The viral RdRp consists of two virus-encoded subunits, a smaller one P and a larger one L. Testing different inactive RdRp mutants with defects throughout the length of the L subunit in pairwise combinations, restoration of viral RNA synthesis was observed in some combinations. This positive L–L interaction is referred to as intragenic complementation and indicates that the L protein is an oligomer in the viral RNA polymerase complex.
Post-crash survivability is the chance that drivers and passengers survive a crash after it occurs. Technology such as Advanced Automatic Collision Notification can automatically place calls to emergency services and send information about a vehicle collision. Cars are much more dangerous to pedestrians than they are to drivers and passengers. Two-thirds of 1.3 million yearly auto related deaths are pedestrians. Since at least the early 1970s, attention has also been given to vehicle design regarding the safety of pedestrians in car-pedestrian collisions. Proposals in Europe would require cars sold there to have a minimum/maximum hood (bonnet) height. From 2006, the use of "bull bars", a fashion on 4x4s and SUVs, became illegal in the European Union, after having been banned on all new cars in 2002. Recent research has explored the use of multimodal sensor fusion to improve pedestrian detection in challenging conditions, including low-light environments and unusual pedestrian postures such as prone or fallen individuals.
Sources: en.wikipedia.org
In the anterior pituitary, the term "acidophil" is used to describe two different types of cells which stain well with acidic dyes. Somatotrophs, which secrete growth hormone (a peptide hormone) Lactotrophs, which secrete prolactin (a peptide hormone) When using standard staining techniques, they cannot be distinguished from each other (though they can be distinguished from basophils and chromophobes), and are therefore identified simply as "acidophils". Eosinophilic Acidophile (histology) Basophilic Chromophobe cell Melanotroph Chromophil Basophil cell Oxyphil cell Oxyphil cell (parathyroid) Pituitary gland Neuroendocrine cell
It is a cyclin dependent kinase containing the catalytic subunit, Cdk9, and a regulatory subunit, cyclin T in Drosophila. In humans there are multiple forms of P-TEFb which contain Cdk9 and one of several cyclin subunits, cyclin T1, T2, and K. P-TEFb associates with other factors including the bromodomain protein BRD4, and is found associated with a large complex of proteins called the super elongation complex. Importantly, for the AIDS virus, HIV, P-TEFb is targeted by the HIV Tat protein which bypasses normal cellular P-TEFb control and directly brings P-TEFb to the promoter proximal paused polymerase in the HIV genome.
In both pharmacology and nutrition sciences, bioavailability is measured by calculating the area under curve (AUC) of the drug concentration time profile. Bioavailability is a term used to describe the percentage of an administered dose of a xenobiotic that reaches the systemic circulation unchanged. It is denoted by the letter f (or, if expressed in percent, by F). In nutritional science, which covers the intake of nutrients and non-drug dietary ingredients, the concept of bioavailability lacks the well-defined standards associated with the pharmaceutical industry. The pharmacological definition cannot apply to these substances because utilization and absorption is a function of the nutritional status and physiological state of the subject, resulting in even greater differences from individual to individual (inter-individual variation). Therefore, bioavailability for dietary supplements can be defined as the proportion of the administered substance capable of being absorbed and available for use or storage.
The idea of Food Social Security stemmed from noticing various flaws inherent to the current food system such as malnutrition, food insecurity, farmers' precarity and environmental concerns. Globally, while enough food is produced to feed ten billion people, food systems are threatening both human health and environmental sustainability. Food bank demand is soaring throughout the world, and is in itself not seen as a long-term response to food insecurity. Poor nutrition is generally linked to lower incomes, causing one of the largest public health challenges for children, and a significant strain on healthcare systems. The three fundamental principles of Food Social Security are:
The enzyme converts adenosine to adenosine monophosphate by transferring a phosphate group. Adenosine diphosphate is produced as a byproduct: The AdK gene/protein is mainly found in eukaryotic organisms and its primary sequence shows a high degree of conservation (>55% aa similarity). However, AdK sequences exhibit low (~ 20-25%), but significant similarity to other PfkB family of proteins such as RK and phosphofructokinases, which are also found in prokaryotic organisms. Although a protein exhibiting AdK activity has been reported in Mycobacterium tuberculosis, sequence and biochemical characteristics of this enzyme reveal it to be an atypical enzyme that is more closely related to ribokinase and fructokinase (35%) than to other ADKs (less than 24%).
Sources: en.wikipedia.org
HPLC separates and detects individual compounds in a liquid sample, producing peaks at characteristic retention times. Peak area or height can be used to estimate concentration when calibrated with known standards. It does not identify unknown compounds with certainty unless additional detectors or reference materials are used.
Pressure drives the liquid mobile phase through a column packed with small particles. Without pressure, flow would be very slow or stop because the packed bed resists liquid movement. Modern pumps maintain a steady flow despite the resistance.
A chromatogram is a plot of detector signal against time after sample injection. Each peak represents a compound or group of compounds eluting from the column. Retention time and peak area are the main measurements read from the plot.
System suitability is a set of checks performed before and during an HPLC run to confirm that the instrument and method are working as expected. It may include retention time repeatability, resolution between peaks, peak symmetry, and signal intensity. Failing suitability criteria usually invalidates the run.