Everything below concerns reversed-phase. We keep the language plain, cite what the science says, and separate well-supported claims from open questions.
Last reviewed on 2025-11-21. Where a claim depends on a specific study, the study is described rather than over-claimed.
Validation establishes that a method is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, robustness, and stability of standards and samples. Acceptance criteria are defined in advance, and results are documented in a validation report. Regulatory guidance for pharmaceuticals, foods, and environmental testing differs, so the applicable framework must be identified. Ongoing verification uses control samples and trend charts after validation. Method transfer to another laboratory may require partial revalidation.
Routine quality control includes blanks, duplicates, spiked samples, and certified reference materials. Calibration curves are prepared with standards at several concentrations, and the detector response is checked for linearity. Carryover, column aging, mobile phase evaporation, and temperature drift can shift retention times or peak areas. Maintenance such as replacing seals, filters, and columns helps prevent failures. Records of injections, integration, and deviations support traceability. Audits may request raw data and instrument logs for each batch.
Developing an HPLC test begins with defining the analytes, matrix, and required reporting limits. Chemists select a separation mode, column chemistry, mobile phase composition, flow rate, and detection wavelength or mass transition. Experiments then adjust these variables to achieve adequate retention, resolution, and peak shape. System suitability tests confirm that the instrument and method perform consistently before sample analysis. Without suitable resolution, quantitative results may be unreliable. Preliminary runs often use scouting gradients to locate retention windows.
Method validation establishes that an HPLC procedure is suitable for its intended use. Key parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Accuracy measures agreement with a true or accepted value, while precision describes repeatability and intermediate precision. Specificity confirms that the method measures the analyte without interference from impurities, degradants, or excipients. Validation is documented in a protocol and report, and acceptance criteria are set before experiments begin. Regulatory guidance varies by region, but the general principles are widely harmonized.
System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Common checks include retention time, peak area, resolution between critical pairs, tailing factor, and theoretical plate count. Results are compared with predefined limits, and a failed check requires investigation before sample results are reported. Quality control samples at low, middle, and high concentrations are injected at intervals to monitor accuracy and precision. Blank injections detect carryover and contamination, while control charts track performance over time.
| Property | Value | Notes |
|---|---|---|
| Accuracy | Closeness to true value | Often assessed by recovery of spiked samples |
| Precision | Agreement among repeated measurements | Often reported as relative standard deviation |
| Specificity | Ability to measure analyte without interference | Must separate analyte from impurities and matrix |
| Linearity | Proportional detector response | Evaluated across a defined concentration range |
| Robustness | Resistance to small method changes | Tests flow rate, pH, temperature, and mobile phase composition |
Several separation modes exist, including reversed-phase, normal-phase, ion-exchange, size-exclusion, and hydrophilic interaction liquid chromatography. Reversed-phase uses a nonpolar stationary phase with a polar mobile phase and is widely applied to small organic molecules. Gradient elution changes mobile phase composition during the run, while isocratic elution keeps it constant. Column chemistry, particle size, temperature, flow rate, and mobile phase pH all influence retention and resolution. Method development selects conditions that separate analytes from matrix components and from each other.
Detection commonly uses ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. Ultraviolet detection depends on molecular chromophores that absorb light at specific wavelengths. Mass spectrometry provides mass information and sensitive quantification, often after electrospray ionization. Before sample batches, performance checks examine resolution, elution time repeatability, peak symmetry, and plate count. Matrix effects and co-elution remain recognized uncertainties; formal validation studies and orthogonal detection help address them. Detector choice depends on analyte properties and required sensitivity.
High-performance liquid chromatography, or HPLC, separates dissolved compounds by passing a liquid mobile phase through a packed column. Components distribute differently between the stationary phase and the moving liquid, so they travel at different speeds and exit at different times. A detector records these eluting bands as peaks, and peak area or height relates to amount. The technique supports testing in pharmaceuticals, foods, environmental samples, and industrial chemicals. Quantification usually depends on calibration with known standards.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. UV detection is widely used because many organic compounds absorb light, but it requires a chromophore. Mass spectrometry provides mass-based identification and high sensitivity for trace analytes. Each detector has trade-offs in selectivity, cost, and compatibility with mobile phases. Quantification typically uses calibration curves prepared from reference standards. Results are reported as concentration, purity, or presence above a limit.
HPLC testing separates dissolved compounds by passing a liquid sample through a column packed with stationary phase. A pump delivers mobile phase at controlled flow, and the sample components interact differently with stationary and mobile phases. Compounds that spend more time in mobile phase elute earlier; those retained by stationary phase elute later. Detectors record elution as peaks, and peak area or height relates to amount. This mechanism underpins quantitative analysis of mixtures.
Most routine HPLC testing uses reversed-phase columns, where the stationary phase is nonpolar and the mobile phase is a polar mixture such as water with an organic solvent. Analytes partition between the two phases according to polarity, size, and charge. Gradients that change solvent composition over time can separate compounds with broad retention ranges. Isocratic conditions keep solvent composition constant and suit simpler mixtures. The choice of column chemistry, pH, and temperature affects selectivity and peak shape.
Documentation and traceability are central to regulated HPLC testing. Records typically include instrument logs, column history, mobile-phase preparation, sample preparation, injection sequences, raw chromatograms, and audit trails. Electronic systems may require user access controls, time-stamped changes, and backup procedures. Training records show that analysts are qualified for assigned methods. Audits and inspections check whether written procedures match actual practice and whether deviations are documented. These controls support reproducibility and allow results to be reconstructed if questions arise later.
Method validation establishes that an HPLC procedure is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, robustness, and solution stability. Accuracy reflects closeness to a reference value, while precision reflects agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from matrix components. Validation is documented through protocols and reports, and the required extent depends on the method's use and regulatory context.
The functional form of single-stranded RNA molecules, just like proteins, frequently requires a specific spatial tertiary structure. The scaffold for this structure is provided by secondary structural elements that are hydrogen bonds within the molecule. This leads to several recognizable "domains" of secondary structure like hairpin loops, bulges, and internal loops. In order to create, i.e., design, RNA for any given secondary structure, two or three bases would not be enough, but four bases are enough. This is likely why nature has "chosen" a four base alphabet: fewer than four would not allow the creation of all structures, while more than four bases are not necessary to do so. Since RNA is charged, metal ions such as Mg2+ are needed to stabilise many secondary and tertiary structures. The naturally occurring enantiomer of RNA is D-RNA composed of D-ribonucleotides. All chirality centers are located in the D-ribose. By the use of L-ribose or rather L-ribonucleotides, L-RNA can be synthesized. L-RNA is much more stable against degradation by RNase. Like other structured biopolymers such as proteins, one can define topology of a folded RNA molecule. This is often done based on arrangement of intra-chain contacts within a folded RNA, termed as circuit topology.
Afucosylated monoclonal antibodies are monoclonal antibodies engineered so that the oligosaccharides in the Fc region of the antibody do not have any fucose sugar units. When antibodies are afucosylated, antibody-dependent cellular cytotoxicity (ADCC) is increased. Most approved monoclonal antibodies are of the IgG1 isotype, where two N-linked biantennary complex-type oligosaccharides are bound to the Fc region. The Fc region exercises the effector function of ADCC through its interaction with leukocyte receptors of the FcγR family. ADCC is important in the efficacy of cancer antibodies, but with many approved cancer antibodies there is less ADCC than could be desired due to nonspecific IgG competing with the drugs for binding to FcγIIIa on natural killer cells. Afucosylated monoclonal antibodies overcome this problem through improved FcγIIIa binding.
The first definition of the term bioinformatics was coined by Paulien Hogeweg and Ben Hesper in 1970, to refer to the study of information processes in biotic systems. This definition placed bioinformatics as a field parallel to biochemistry (the study of chemical processes in biological systems). Bioinformatics and computational biology involved the analysis of biological data, particularly DNA, RNA, and protein sequences. The field of bioinformatics experienced explosive growth starting in the mid-1990s, driven largely by the Human Genome Project and by rapid advances in DNA sequencing technology. Analyzing biological data to produce meaningful information involves writing and running software programs that use algorithms from graph theory, artificial intelligence, soft computing, data mining, image processing, and computer simulation. The algorithms in turn depend on theoretical foundations such as discrete mathematics, control theory, system theory, information theory, and statistics.
Sources: en.wikipedia.org
The predecessor of modern countercurrent chromatography theory and practice was countercurrent distribution (CCD). The theory of CCD was described in the 1930s by Randall and Longtin. Archer Martin and Richard Laurence Millington Synge developed the methodology further during the 1940s. Finally, Lyman C. Craig introduced the Craig countercurrent distribution apparatus in 1944 which made CCD practical for laboratory work. CCD was used to separate a wide variety of useful compounds for several decades.
Calmodulin-like protein 5 is a protein that in humans is encoded by the CALML5 gene. This gene encodes a novel calcium binding protein expressed in the epidermis and related to the calmodulin family of calcium binding proteins. Functional studies with recombinant protein demonstrate it does bind calcium and undergoes a conformational change when it does so. Abundant expression is detected only in reconstructed epidermis and is restricted to differentiating keratinocytes. In addition, it can associate with transglutaminase 3, shown to be a key enzyme in the terminal differentiation of keratinocytes. Human CALML5 genome location and CALML5 gene details page in the UCSC Genome Browser. Overview of all the structural information available in the PDB for UniProt: Q9NZT1 (Human Calmodulin-like protein 5) at the PDBe-KB.
Small clusters of cas genes are often located next to CRISPR repeat-spacer arrays. Collectively the 93 cas genes are grouped into 35 families based on sequence similarity of the encoded proteins. 11 of the 35 families form the cas core, which includes the protein families Cas1 through Cas9. A complete CRISPR-Cas locus has at least one gene belonging to the cas core. CRISPR-Cas systems fall into two classes. Class 1 systems use a complex of multiple Cas proteins to degrade foreign nucleic acids. Class 2 systems use a single large Cas protein for the same purpose. Class 1 is divided into types I, III, and IV; class 2 is divided into types II, V, and VI. The 6 system types are divided into 33 subtypes. Each type and most subtypes are characterized by a "signature gene" found almost exclusively in the category. Classification is also based on the complement of cas genes that are present. Most CRISPR-Cas systems have a Cas1 protein. The phylogeny of Cas1 proteins generally agrees with the classification system, but exceptions exist due to module shuffling. Many organisms contain multiple CRISPR-Cas systems suggesting that they are compatible and may share components. The sporadic distribution of the CRISPR-Cas subtypes suggests that the CRISPR-Cas system is subject to horizontal gene transfer during microbial evolution.
Laboratory testing in the United States is subject to federal regulation. Clinical laboratories performing testing are overseen by the Centers for Medicare and Medicaid Services (CMS) utilizing national standards established under the Clinical Laboratory Improvement Amendments (CLIA). The Centers for Disease Control and Prevention (CDC) and the Food and Drug Administration (FDA) assist CMS in this process. CMS ensures the integrity of laboratories performing testing via inspections and consistent oversight, bolstered with proficiency testing by accredited organizations. CLIA authorizes regulation of laboratories that conduct testing, not the individuals who order the tests or receive test results. All laboratories performing DTC testing must obtain CLIA certification and maintain compliance with national standards.
Sources: en.wikipedia.org
PABA is an intermediate in the synthesis of folate by bacteria, plants, and fungi. Many bacteria, including those found in the human intestinal tract such as E. coli, generate PABA from chorismate by the combined action of the enzymes 4-amino-4-deoxychorismate synthase and 4-amino-4-deoxychorismate lyase. Plants produce PABA in their chloroplasts, and store it as a glucose ester (pABA-Glc) in their tissues. The malarial protozoan Plasmodium only make PABA when necessary, preferring to get it from the surroundings if able to. Some bacteria, including a few found in the human microbiome, are unable to make PABA for themselves but can use PABA to make folate. A few are very efficient at the PABA-to-folate conversion despite not making their own PABA. Sulfonamide drugs are structurally similar to PABA, and their antibacterial activity is due to their ability to interfere with the conversion of PABA to folate by the enzyme dihydropteroate synthetase. Thus, bacterial growth is limited through folate deficiency.
Förster resonance energy transfer (FRET)-based Cl indicators consist of two fluorescent proteins, Cyan fluorescent protein (CFP) and YFP connected via a polypeptide linker. This allows ratiometric Cl− measurements based on the Cl− sensitivity of YFP and Cl− insensivity of CFP. Clomeleon and Cl− Sensor are FRET-based Cl indicators that allow ratiometric non-invasive monitoring of chloride activity in living cells.
This technology entails the joining of DNA from different species and the subsequent insertion of the hybrid DNA into a host cell. One of the first individuals to develop recombinant DNA technology was a biochemist at Stanford by the name of Paul Berg. In his experimental design in 1974, he cleaved (cut into fragments) the monkey virus SV40. He then cleaved the double helix of another virus, an antibacterial agent known as bacteriophage lambda. In the third step, he fastened DNA from the SV40 to DNA from the bacteriophage lambda. The final step involved placing the mutant genetic material into a laboratory strain of the E. coli bacterium. This last step, however, was not completed in the original experiment.
Bruce Randall Donald (born 1958) is an American computer scientist and computational biologist. He is the James B. Duke Professor of Computer Science and Biochemistry at Duke University. He has made numerous contributions to several fields in Computer Science such as robotics, Microelectromechanical Systems (MEMS), Geometric & physical algorithms and computational geometry, as well as in areas of Structural Molecular Biology & Biochemistry such as Protein design, Protein Structure Determination and Computational Chemistry.
The therapeutic index (TI) is used to quantify the risks and benefits of a certain drug. It describes the relationship between toxic dose and minimum effective dose, thus providing an important insight into the safety of a drug. The Therapeutic Index is calculated using the following equation: TI = TD50 / ED50, where TD50 is the dose at which toxicity presents in 50% of the population, and ED50 is the dose needed to produce 50% of maximal response. From the equation, a high TI indicates that the drug needs a high dose to induce toxicity in 50% of the population or a low dose to achieve the minimum effective dose, and vice versa. In the case of physiological antagonists, for example, insulin has a narrow TI. A narrow TI indicates that either excess or lack of insulin can cause significant risks. On one hand, lack of insulin may result in high blood glucose levels and kidney or cardiovascular damage. On the other hand, excess insulin may result in insulin-induced hypoglycemia as aforementioned. Another example is dimercaprol, a chemical antagonist in treating metal toxicity. Dimercaprol has a narrow TI so it is replaced by its derivative, 2,3-dimercaptosuccinic acid (DMSA).
Sources: en.wikipedia.org
System suitability is a set of checks performed before and during a run to confirm that the instrument, column, and method work as expected. Common checks include resolution, tailing factor, theoretical plates, and relative standard deviation of replicate injections. Failure triggers troubleshooting or method adjustment.
Validation demonstrates that a method produces reliable results for a defined purpose. It documents performance limits and acceptance criteria. Regulated industries require validation before routine testing of products or samples.
Retention time shifts can arise from changes in mobile phase composition, pH, temperature, column age, or flow rate. Contamination or worn seals may also alter pressure and delivery. Systematic checks of these factors help identify the cause.
System suitability is a set of checks that confirm the instrument and method perform within limits before sample analysis. It typically includes resolution, tailing factor, retention time, and peak area reproducibility. If a check fails, the run is invalidated until the cause is resolved.