If you have been reading about quality control and want a single page that covers the useful parts, this is it: definitions, context, how it is studied, and the questions that come up repeatedly.
Last reviewed on 2025-12-15. Where a claim depends on a specific study, the study is described rather than over-claimed.
Routine HPLC testing compares a sample result with a calibration curve prepared from known reference standards. Peak area or peak height is plotted against concentration, and the curve is used to estimate unknown amounts. Retention time supports tentative identification when compared with a standard, though mass spectrometry or another confirmatory method may be needed for definitive identification. Pre-run checks verify repeatability, resolution, and peak symmetry before sample analysis. Limits of detection and quantification describe the smallest amounts that can be reliably observed or measured. Sample preparation, filtration, and degassing help prevent column damage and inconsistent results.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample. A pump moves a liquid mobile phase through a column packed with a solid stationary phase. Compounds interact differently with both phases and travel at different rates, leaving the column at distinct retention times. A detector records these arrivals as peaks on a chromatogram. The resulting pattern supports identification and quantification of substances in mixtures. Modern instruments use high pressure to force solvent through small particles, which improves speed and resolution compared with older low-pressure liquid chromatography methods.
Separation in HPLC depends on the chemistry of the stationary phase, the composition of the mobile phase, and the physical properties of the column. Reverse-phase separations use a nonpolar stationary phase and a polar mobile phase, and they are common for many organic compounds. Ion-exchange, size-exclusion, and normal-phase modes serve other classes of analytes. Gradient elution changes solvent strength over time, while isocratic elution holds it constant. Flow rate, temperature, particle size, and column length all influence peak shape and resolution. Detection may use ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry, depending on the analyte and the required sensitivity.
Reversed-phase chromatography dominates modern HPLC testing, using a nonpolar stationary phase such as chemically bonded octadecyl groups and a polar mobile phase of water mixed with organic solvent. Analytes partition between the mobile and stationary phases according to hydrophobicity. Gradient elution changes the mobile phase composition over time to separate compounds with a wide range of retention. Isocratic elution keeps the composition constant and is simpler for routine assays. Column temperature, pH, and flow rate influence selectivity, peak shape, and retention time, so these parameters are controlled during a validated method.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. A diode array detector records full spectra across a wavelength range, which helps identify co-eluting peaks. Mass spectrometry provides mass-to-charge ratios and can confirm molecular identity at low concentrations. The choice of detector depends on analyte structure, required sensitivity, and whether quantitation or identification is the goal. No single detector works for every compound, and method development often compares responses before selecting one.
High-performance liquid chromatography is an analytical technique that separates components of a liquid sample by passing it through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in interaction with the stationary phase cause analytes to migrate at different rates. Detectors record elution as peaks, and a data system converts signals into a chromatogram. The method is suited to compounds that dissolve in a liquid and are not volatile enough for gas chromatography.
| Property | Value | Notes |
|---|---|---|
| Common abbreviation | HPLC | High-performance liquid chromatography |
| Separation basis | Differential partitioning | Between liquid mobile phase and solid stationary phase |
| Common mode | Reverse phase | Nonpolar column, polar mobile phase |
| Typical detector | UV-Vis absorbance | Widely used for compounds with chromophores |
| Typical column particle size | 2–5 µm | Smaller particles can improve resolution |
Method validation establishes that an HPLC procedure is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, robustness, and solution stability. Accuracy reflects closeness to a reference value, while precision reflects agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from matrix components. Validation is documented through protocols and reports, and the required extent depends on the method's use and regulatory context.
Routine quality control uses system suitability, blank injections, check standards, and control samples to detect drift or contamination. System suitability criteria may specify minimum resolution, maximum tailing factor, and a permitted range for repeated injections. Blank injections reveal carryover or solvent contamination, while check standards confirm calibration accuracy over a batch. Control samples with known analyte levels can show whether results remain within statistical limits. When a control result falls outside limits, the analyst investigates the cause and may invalidate affected results before repeating the batch.
Method validation evaluates accuracy, precision, specificity, linearity, range, detection limit, quantitation limit, and robustness. Regulatory guidance for pharmaceuticals, foods, and environmental testing defines expected documentation and acceptance criteria. Verification confirms that a validated method works in a specific laboratory with its own instruments and reagents. Calibration curves use reference standards with known purity and traceability, while measurement uncertainty is estimated from validation data, control charts, and collaborative studies. The scope of validation depends on the method's intended use.
Routine quality control monitors retention time shifts, baseline noise, system pressure, and peak shape. Trends can reveal column aging, mobile phase preparation errors, detector drift, or sample degradation. Corrective actions may include replacing the column, preparing fresh mobile phase, or recalibrating the detector. Stability testing often uses HPLC to measure parent compound loss and degradation product formation. Open questions remain about how accelerated stability results extrapolate to long-term storage under varied conditions.
Quality control for HPLC testing combines scheduled checks, documented procedures, and review of results. Before sample analysis, system suitability testing confirms that the instrument, column, and method meet predefined criteria. Common criteria include resolution between critical peaks, retention time precision, peak tailing, and theoretical plate count. Failure triggers investigation before results are reported. Records link raw data, calculations, instrument logs, and analyst identity to each batch, supporting audits and repeat analysis.
Quality control samples are inserted at intervals to monitor accuracy and precision throughout a batch. Blank samples detect contamination, while spiked samples assess recovery from the sample matrix. Calibration standards establish the relationship between detector response and concentration, and control samples are prepared independently from them whenever possible. Laboratories also participate in proficiency testing and maintain audit trails, instrument logs, and reagent records. Ongoing review of control charts can reveal trends before they cause out-of-specification results.
Method validation demonstrates that an HPLC procedure is suitable for its intended purpose. Common validation parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, and robustness. Accuracy reflects agreement with a reference value, while precision describes repeatability under defined conditions. Specificity shows whether the method can measure the analyte in the presence of impurities or matrix components. Validation documents are reviewed before a method is used for routine testing or regulatory submissions.
System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Typical checks include retention time, peak area precision, resolution between critical pairs, tailing factor, and theoretical plate count. Acceptance criteria are set in the method or pharmacopeial monograph. If a suitability check fails, the run may be rejected and the instrument or sample preparation may need investigation. This practice helps prevent release of data from a system that has drifted out of control.
Validation establishes that a method is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, robustness, and stability of standards and samples. Acceptance criteria are defined in advance, and results are documented in a validation report. Regulatory guidance for pharmaceuticals, foods, and environmental testing differs, so the applicable framework must be identified. Ongoing verification uses control samples and trend charts after validation. Method transfer to another laboratory may require partial revalidation.
Routine quality control includes blanks, duplicates, spiked samples, and certified reference materials. Calibration curves are prepared with standards at several concentrations, and the detector response is checked for linearity. Carryover, column aging, mobile phase evaporation, and temperature drift can shift retention times or peak areas. Maintenance such as replacing seals, filters, and columns helps prevent failures. Records of injections, integration, and deviations support traceability. Audits may request raw data and instrument logs for each batch.
ACTA2 (actin alpha 2) is an actin protein with several aliases including alpha-actin, alpha-actin-2, aortic smooth muscle or alpha smooth muscle actin (α-SMA, SMactin, alpha-SM-actin, ASMA). Actins are a family of globular multi-functional proteins that form microfilaments. ACTA2 is one of six different actin isoforms and is involved in the contractile apparatus of smooth muscle. ACTA2 (as with all the actins) is extremely highly conserved and found in nearly all mammals. In humans, ACTA2 is encoded by the ACTA2 gene located on 10q22-q24. Mutations in this gene cause a variety of vascular diseases, such as thoracic aortic disease, coronary artery disease, stroke, Moyamoya disease, and multisystemic smooth muscle dysfunction syndrome. ACTA2 (commonly referred to as alpha-smooth muscle actin or α-SMA) is often used as a marker of myofibroblast formation. Studies have shown that ACTA2 is associated with TGF-β pathway that enhances contractile properties of hepatic stellate cells leading to liver fibrosis and cirrhosis.
The Department of Mines and Petroleum was a department of the Government of Western Australia until it was superseded by the Department of Mines, Industry Regulation & Safety on 1 July 2017. The department was formed on 1 January 2009, out of the former Department of Industry & Resources and Department of Consumer & Employment Protection, which were split into three new departments, the Department of Mines & Petroleum, the Department of State Development and the Department of Commerce. Its focus is the resources sector, maintaining a mining and petroleum regulatory role and incorporating the resources safety responsibilities from the former Department of Consumer & Employment Protection. It also oversees the Geological Survey of Western Australia. The department operates the Mindex website, a continuously updated database containing information on mines, mineral deposits and prospects in Western Australia.
Yeast artificial chromosome or YAC is a DNA molecule that is developed by humans to take the DNA sequences that belong to yeast cells and clone them. Yeast artificial chromosomes can be inserted with fragments of DNA from the organism of interest. Yeast cells will then assimilate the yeast artificial chromosome that contains the DNA from the organism of interest. The yeast cells then multiply in number and this brings about the amplification of the DNA that has been incorporated into it which is then isolated for the purpose of things like sequencing and mapping of the DNA desired i.e. the DNA originally inserted into the yeast artificial chromosome. Vectorette PCR helps with this process by bringing about not only the isolation of the yeast artificial chromosome’s ends but also the amplification of the ends.
A22, also known as S-(3,4-dichlorobenzyl) isothiourea, is a chemical compound with antibiotic activity. It is colorless, hygroscopic, and light-sensitive. A22 acts as a reversible inhibitor of the bacterial cell wall protein MreB, causing bacterial rod-shaped cells to form coccoid cells. The antibiotic activity of A22 has been studied primarily in Pseudomonas aeruginosa. However, A22 does not seem to be useful as an antibiotic in humans due to its cytotoxic and genotoxic effects on human peripheral blood mononuclear cells (PBMCs). Despite its cytotoxic effects in human cells, A22 has been used as a research tool to investigate the bacterial cytoskeleton. A22 binds directly to the actin homolog MreB in its nucleotide-binding pocket, blocking simultaneous ATP binding. As a consequence, A22 inhibits MreB polymerization and thus disrupts the cytoskeleton of bacteria, causing defects of morphology and chromosome segregation.
Sources: en.wikipedia.org
44. Adv Gerontol. 2004;13:90-3. [Effect of epitalon on the immunity and hemostasis in hypophysectomized chicken and old hens]. [Article in Russian] Kuznik BI, Pateiuk AV, Khavinson VKh, Malinin VV. Neonatal hypophysectomy in chicken, as well as that in old hen has been established to entail in 1,5 months after surgery cellular and humoral immunity disturbances, pronounced hypercoagulation and fibrinolysis depression. Administration of Epitalon (Ala-Glu-Asp-Gly) to a large extent eliminates revealed shifts. This effect appeared to be stronger in neonatally hypophysectomized chicken than in old hens.
Amphetamine-Dextroamphetamine is known to hamper appetite. Amphetamine-Dextroamphetamine is used to treat Attention deficit hyperactivity disorder (ADHD) and is usually under the trade name "Adderall" or "Mydayis". Amphetamine sulfate (also known as amfetamine) – US FDA-approved for the treatment of exogenous obesity under the brand name "Evekeo". Methylphenidate Cocaine Caffeine Glucomannan Leptin Lisdexamfetamine - US FDA approved for the treatment of binge-eating disorder in adults under the brand name "Vyvanse". Methamphetamine hydrochloride – USFDA-approved for the treatment of obesity (as a short-term) under the brand name "Desoxyn". Nicotine Liraglutide as brand name Saxenda Semaglutide (brand name Ozempic/Wegovy) GLP-1 agonist Tirzepatide (Brand Name Mounjaro, Zepbound) Metformin Opiates/opioids such as heroin, morphine, codeine, oxycodone, fentanyl, etc. Anti-obesity medication
Dietary supplement companies aggressively promote NMN products claiming these benefits. NMN is a precursor to NAD+ biosynthesis, and dietary NMN supplementation has been shown to increase NAD+ concentrations and thus has the potential to mitigate aging-related disorders such as oxidative stress, DNA damage, neurodegeneration, and inflammatory responses. The potential benefits and risks of NMN supplementation as of 2023 are currently under study. Life extension Anti-aging movement
Sources: pubmed.ncbi.nlm.nih.gov
ISOLDE contains both temporary and fixed experimental setups. Temporary setups in the ISOLDE facility are there for shorter time periods, and generally focus on detecting specific decay modes of nuclei. The fixed experimental setups have a permanent position at the facility. They include: The COLinear LAser SPectroScopy (COLLAPS) experiment has been operating at ISOLDE since the late 1970s and is the oldest active experiment at the facility. COLLAPS studies ground and isomeric state properties of highly-unstable (exotic), short-lived nuclei, including measurements of their spins, electro-magnetic moments and charge radii. The experiment uses the technique of collinear spectroscopy using lasers to access necessary atomic transitions. The Collinear Resonance Ionization Spectroscopy (CRIS) experiment uses fast beam collinear laser spectroscopy alongside the technique of resonance ionization to produce results with a high resolution and efficiency. The experiment studies group-state properties of exotic nuclei and produces isomeric beams used for decay studies.
Ancestim is a recombinant methionyl human stem cell factor, branded by Amgen as StemGen. It was developed by Amgen and sold to Biovitrium, now Swedish Orphan Biovitrum, in December, 2008. It is a 166 amino acid protein produced by E. coli bacteria into which a gene has been inserted for soluble human stem cell factor. It has a monomeric molecular weight of approximately 18,500 daltons and normally exists as a noncovalently associated dimer. The protein has an amino acid sequence that is identical to the natural sequence predicted from human DNA sequence analysis, except for the addition of an N-terminal methionine retained after expression in E. coli. Because Ancestim is produced in E. coli, it is nonglycosylated. Ancestim is supplied as a sterile, white, preservative-free, lyophilised powder for reconstitution and administration as a subcutaneous (SC) injection and is indicated for use in combination with filgrastim for mobilizing peripheral hematopoietic stem cells for later transplantation in certain cancer patients.
Because DNA collects mutations over time, which are then inherited, it contains historical information, and, by comparing DNA sequences, geneticists can infer the evolutionary history of organisms, their phylogeny. This field of phylogenetics is a powerful tool in evolutionary biology. If DNA sequences within a species are compared, population geneticists can learn the history of particular populations. This can be used in studies ranging from ecological genetics to anthropology. DNA as a storage device for information has enormous potential since it has much higher storage density compared to electronic devices. However, high costs, slow read and write times (memory latency), and insufficient reliability has prevented its practical use.
Recent data showed that Synacthen test results can be used to predict future recovery of HPA axis function in patients with reversible causes of Adrenal Insufficiency. == Other hormones and chemicals that will rise in the ACTH stimulation test == Progesterone – precursor to cortisol and aldosterone 17α-Hydroxyprogesterone – a progestogen steroid hormone related to progesterone Luteinizing hormone – a pituitary hormone that stimulates sex hormone production DHEA and DHEA-S – androgen hormones produced in the adrenal glands The test is also used to diagnose hypoadrenocorticism in dogs and sometimes cats. Dexamethasone suppression test Insulin tolerance test, another test used to identify sub-types of adrenal insufficiency Metyrapone, a drug used in the diagnosis of adrenal insufficiency Triple bolus test Renin, enzyme that converts angiotensinogen 1 to angiotensin 2, a precursor to aldosterone Renin–angiotensin–aldosterone system HPA axis, explains the connections of the hypothalamus, pituitary and adrenal glands Hypopituitarism Pituitary adenoma Adrenal adenoma Corticorelin
Sources: en.wikipedia.org
HPLC testing measures the presence and amount of one or more compounds in a liquid sample. It separates mixture components and records detector responses as peaks, which are compared with reference standards. Results are usually reported as concentrations or relative percentages.
Retention time is the interval between sample injection and the detector response for a given compound. It depends on the compound's interactions with the stationary and mobile phases under set conditions. Matching a retention time to a standard supports tentative identification but is not always unique.
HPLC alone can separate unknown compounds and provide retention times, but it often cannot identify them with certainty. Coupling HPLC to mass spectrometry gives mass information that improves identification. Confirmation usually requires comparison with reference standards or complementary techniques.
HPLC testing separates and quantifies components in a liquid sample. It is used to check identity, purity, concentration, or stability. The technique works best for compounds that dissolve and are not easily vaporized.